24 Live Notices for 扩张器招标
Showing 1 to 20
Open Auction On Line Electrophysiology And Ablation Cpv Code 33141200-2;
Open Auction On Line Castra Electrophysiology And Ablation Cpv Code 33141200-2;
Object: Electronic Auction - Acquisition Of Specific Inputs For Surgeries In The Surgical Block Of The University Hospital Of Brasilia - Hub, Referring To Trading Session 90.005/2025.
Object: Electronic Auction - Track Assembly And Others
Object: Electronic Auction - Track Assembly And Others
Object: Electronic Auction - The Object Of The Bidding Is The Price Registration For Future And Eventual Acquisitions Of Hospital Medical Material, Under The Conditions Established In This Notice And Its Attachments.
Open Procedure Above Community Threshold, Pursuant To Art. 71 Of Legislative Decree 36/2023, For The Assignment Of The Supply Of Medical Devices For Cateterism In Acute And Permanent Hemodialysis Divided Into 10 Lots, For A Period Of 36 Months To Be Awarded With The Criterion Of The Economically More Advantageous Offer On The Basis Of The Best Quality/Price Ratio
Medical Consumables - Dns
Supply of Medicine and Medical / Surgical equipments : Seldinger intercostal Catheter kit 12FG\nThe drain Catheter 12FG, 30cm or more\nin length.\nClear polyvinyl or other transparent and\nflexible material.\nRadio opaque line along the drain to\nvisualize the tube by X ray with the most\nproximal side hole placed on the radio\nopaque line.\nLength of the tube marked clearly in\ncentimetres on the tube to conveniently\ndetermine the skin level of the tube\nwhen\ninserted\nThe proximal end of the tube should be\ncompatibility with a 3 way tap to\naspirate, flush or to do medical\npleurodesis.\nAll the connectors needed to connect the\ncatheter to the underwater seal should\nbe included in the pack.\nDilator\n10cm dilator and or safety locks in longer\ndilators Length of insertion should be\nmarked on the dilator if it is more than\n10cm\nGuide wire.\nShould be adequately longer than the\nlength of the catheter so that the wire\nwill be always visible to the operatorat\nevery stage during the procedure. (ie will\nnot be pushed into the pleural space\ninadvertently while inserting the\ncatheter. (Preferably twice the length of\nthe tube)\nPreferably visible by ultrasound\nPreferably supplied with a guide wire\nholder for easy handling at insertion\nIntroducer needle-\nAt least 7 cm in length\nLength of insertion marked in\ncentimetres\nPreferably a side port to introduce the\nguide wire\nPreferably visible by ultrasound\nPreferable-\nTo include in the pack, all syringes, etc .
Multilot Open Procedure For The Assignment Of The Supply Of Acute And Permanent Hemodialysis Catheterism For A Period Of 36 Months
Cardiovascular Surgery Supplies Insurance
Cardiovascular Surgery Supplies Insurance
Urgent Medical Insurance
Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Catheters Are Intravenous; Catheters Are Intravenous; Catterization Set Is 2-Channel, Catheter 5Fr 13 Cm Long, Syringe 5Ml, J Conductor 50Cm Long, 6F Dilator,… Still
Gloves Inspection, Non-Sterile, Nitrile, Without Powder, Size (Dstu En 455-2: 2015), L; Gloves Inspection, Non-Sterile, Nitrile, Without Powder, Size (Dstu En 455-2: 2015), M; Catheter Urological, Sterile, Disposable, Dual-Channel (2-Way), Size: 16 Fr, Volume Of Cylinders: 30 Milliliters, Length:… Still
Skarifier Ordinary, Spear; Lancet Automatic, 21G Needle, Puncture Depth 1.8Mm; Urine Intake Container Without Graduation, Not Resistant To Autoclaving, 120 Ml; Catheterization Set Is 1-Channel, Catheter 5 Fr, Length From 20 Cm, Dilator, 6 F Syringe 5Ml, J Conductor Length From… Still
Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Needle For Spinal Anesthesia; Catheters Are Intravenous; Catheters Are Intravenous; Catterization Set Is 2-Channel, Catheter 5Fr 13 Cm Long, Syringe 5Ml, J Conductor 50Cm Long, 6F Dilator,… Still
Introduer Radial 6F. Nz Vc # 182 Head Of Intervention Cardiology)
6F Intrader, For Transrodial Access, From 110 Mm, With A Hemostatic Valve And A Lateral Port With A 3-Pass Crane, A Vascular Dilator With A Port For Luer Syringe, A Conductor For Installation Of The Device, An Angiographic Needle 20Gx38Mm; Angiographic Catheter, External Ø: 6 Fr, Vn Ø: 0,055 ", L:… Even Yet
Cattering Set Is 2-Channel, Catheter 7 Fr, Length From 20 Cm, Dilator, 7 F Syringe 5Ml, J Conductor Length Of 60 Cm, Scalpel Set