Description |
1. TENDER NOTICE Delhi & District Cricket Association (DDCA) invites sealed Request for Proposal (RFP) from reputed Contractors for renovation of common toilets work in Wing –A,B,C and Gate 2 & 3 and Hill - A at the Arun Jaitley Stadium. Sealed Tender are invited for renovation of common toilets work in Wing – A, B, C and Gate 2 & 3 and Hill - A at the Arun Jaitley Stadium. The RFP under Quality and Cost Based Selection method invited in Two Bid System from competent Company / Firm/ Agency, who satisfy the eligibility criteria enumerated in the tender document (RFP). Interested Agencies may download the tender documents from the DDCA website: https://ddca.in/ddca-document/tender. The RFP is being called to assess and approve the proposed ‘concept, design and specifications’ submitted by the applicants. After assessment of the proposal by the competent authority / selection committee, Price quotation of only the Approved Bidders shall be opened and the work will be awarded as per terms and conditions of DDCA. Last date for submission of RFP is 28/02/2023 up to 15:00. Sealed envelope marked to the captioned address, containing RFP may be dropped in drop box specially kept for the subject RFP mentioning “Request for Proposal for renovation of common toilets work in Wing – A, B, C and Gate 2 & 3 and Hill - A at the Arun Jaitley Stadium. On the top cover at the following address: The Delhi and District Cricket Association (DDCA) Arun Jaitley Stadium Feroz Shah Kolta Ground New Delhi – 110002 Work completion period: months EMD: 2% of total project cost by way of a demand draft from a Nationalized or Commercial Scheduled Bank. Sr. No. Description Date Time 1 Publishing Date 18/02/2023 10:00 AM 2 Document Download Start Date 18/02/2023 10:00 AM 3 Document Download End Date 28/02/2023 03:00 PM 4 Bid Submission Start Date 18/02/2023 10:00 AM 5 Bid Submission End Date 28/02/2023 03:00 PM 6 Bid Opening Date 28/02/2023 05:00 PM DDCA reserves the right to accept or reject any/all RFP without assigning any reason whatsoever. 2. Background a) Arun Jaitley Stadium is an International Cricket Stadium. b) There is a requirement to renovation of common toilets work in Wing – A, B, C and Gate 2 & 3 and Hill - A at the Arun Jaitley Stadium. a) Design, execute - world class quality for renovation of common toilets work in Wing – A, B, C and Gate 2 & 3 and Hill - A b) The submission of RFP doesn’t guarantee the allotment of the work/ contract. 3. Description of work ( Annexure –A) Sample of common toilet (Sample layout Attached) and BOQ for this work under below as annexure –A S.No. Description of work Unit Qty Rate Amont 1 Dismantling and disposal of all the dismanted part complete Lot 1 2 Providing and laying to pattern tile flooring for called of areas., using tiles of approved size, colour and make to pattern over 20mm thick or more cement mortar bed (to make up required finished floor level) of 1:6 mix including joints shall be pointed with the matching epoxy grout as recommended by Laticrete/ Ardex Endura or approved equivalent make and acid washing, etc., the rate inclusive of providing necessary spacers of size 2~3mm to ensure uniform joints etc. complete. Allow for plastic sheet and POP protective layers, removal and cleaning up, with all lead and lift and as directed by Project Consultant/Engineer in charge Base Rate 80 Rps Per Sft Sqm 244 3Providing and Fixing in position] Tile of approved make, size 600mm x 600mm, colour and shade for cladding in approved pattern to true line and level on average 19 mm thk backing coat plaster in 1:4 mix cement sand mortar, 1:1 cement grout, filling the joints with white / colour cement including cleaning, watering, curing, filling, Edge Polishing (if visible), etc. complete as per detail drawing, as specified and as directed by Project Manager. Base Rate 80 s S q m 525 Rps Per Sft 4Brick partitions with tiles finish as approved by the Advisor(Architecture) DDCA 2400mm high R m 30 5Providing and Fixing 12 mm thk MR grade gypsum board of approved make on metallic grid conforming to IS:2095:1982. Focus on acheiving a smooth finish on the surface. The metallic grid shall consist of the following components: GI Perimeter of size 27 mm and 0.5 mm thk having one flange of 20 mm and another flange of 30 mm. GI Intermediate channel of size 45 mm and 0.5 mm thk with two flange of 15 mm each at 1200 mm centre to centre. GI Hanger of size 25 mm, 0.8 mm to 0.9 mm thk at 1200 mm centre to centre distance. GI Cleat and Steel Expansion Fasteners Ceiling section of 0.5 mm thickness having curled wedge of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm at 600 mm centre to centre. Connecting clips & 12.5 mm drywall screws at 230 mm centre to centre. The metallic grid shall be installed as follows : The perimeter channel along the perimeter ceiling with screw fixed to brick wall partition with the help of rawl plugs and screws. Joint treatment of ceiling board. Edge treatment at cove junction. The intermediate channels shall be suspended from the ceiling with steel GI cleat and steel expansion fasteners. The intermediate channels shall be at 1200 mm centre to centre distance. The ceiling section placed in a direction perpendicular to the Intermediate channels shall be at 600 mm centre to centre distance including 50 mm thk x 150 mm wide Recessed, etc. complete as per detail drawing, as specified and as directed by Project Manager. with cove light S q m 244 5Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections , of size 65 mm x 55 mm with wall thickness |