Description |
Two stage water purification for system(two independent system) for Type 1 and Type 2 Should have DI Technology To Remove Ions As Contaminants from Type 2 water Constant quality & continuous performance Tank level sensors should be there Provision to prevent back flow on Reverse Osmosis Recirculation Loop from tank to DI is required for keeping the tank water clean and fresh. Hand dispenser from the Reservoir to draw Type 2 water. Specifications for I’ltrapurc (Type II) Water Purification System System should be stand-alone Type-II water purification system, suitable for Biological research application. System should be suitable to work with the water quality of up to 200CpS/cm conductivity. Fouling Index (Silt Density Index) < 7, Total Chlorine < 3 ppm. PH: 4-10. produce Ultrapure Water with 4 to lOMQ.cm @25 °C resistivity The system should have the production capacity of 401iter/hour System should have Pre Filtration unit to counter the Iron content in water, particulate load Pre-filtration: 10 Micron filter,5 Micron filter and 3 Micron filter. System should have Pretreatment Cartridge with Activated Carbon and 0.5 Micron Filter. System should have High Quality Thin film composite membrane RO which should be capable of achieving 99% rejection of Ions and all dissolved organics. The system should have Recirculation Loop from tank to DI is required for keeping the tank water clean and fresh. System should have Cartridges with high recovery loop to reduce the wastage of feed water to drain. Also it should have conductivity cell before and after RO to measure performance of RO membranc.RO waste water recovery should be up to 50%. System should have the Electro De-ionization module (EDI Module), with mixed Bed Ion Exchange Resin, so that Regeneration of the Resins happens on application of Electric current.EDI (Electro Deionization) module should not require softening pre-treatment. System should have Auto diagnostic facility with Error NO and Alarm Code and real time clock to log reports with date and time to ensure complete traceability. System should have Automatic Cleaning. Rising, and Flush mode. The system should have Auto testing facility to measure all the parameters like inlet pressure, pressure on RO cartridge. DI Module, flush and rinsing etc System should have suitable screen and user friendly GUI to check all parameters related to purification, storage and distribution. 2 . DUE DATE FOR SUBMISSION OF QUOTATION AGAINST THIS ENQUIRY IS 29/04/2023 BY 5.30PM. 3 .QUOTATIONS RECEIVED AFTER THE DUE DATE SHALL BE REJECTED. 4 .The validity of your quotation should be for 60 days from the due date. 5 .A1I duties, taxes, surcharge and cess as currently applicable must be stated in your quotation, separately. Otherwise your quote is liable to be rejected. 6 .Your quotation should indicate delivery period & warranty period. 7 .Delivery to be made to our stores. Please indicate charges, if any extra. Transit Insurance should be done upto CCAMP Stores. 8.1 f you arc unable to supply the quality, specifications or brand as mentioned in our enquiry,please state so and then offer alternative to quality/specifications. 9 .Payment: within one month after delivery & acceptance/satisfactory installation. lO .Pleasc ensure that the enquiry number and the due date is superscribed on the envelope failing which your quotation is liable to be rejected. H. If the item is covered under DGS&D rate contract, please quote the rate as per the DGS&D rate contract with xerox copy of the DGS&D order. 12.Any dispute or differences that may arise between the parties shall be referred to the sole arbitration of the Centre Director or his nominees. The decision of the arbitrator shall be final and binding on the parties. The venue for arbitration shall be Bangalore. The provisions of the Arbitration and Conciliation Act, 1996 as amended from time to time shall apply. The courts in Bangalore shall have exclusive jurisdiction to deal with any or all disputes between the parties 13.Since we are a research institution, we are exempted from paying Customs duty (Except advolerum duty of 5% + 2%Cess and 1% Cus Sec & High Edu. CESS vide Notification No.51/96 with latest amendments) and excise duty vide Notification No. 10/97 CENTRAL EXCISE dated 01-03-1997 for all scientific equipments, technical instruments, equipments (including computers), their accessories, spares,consumables and software. Hence, please offer your prices 14.1f the item is covered under DGS&D rate contract, please quote the rate as per the DGS&D rate contract with xerox copy of the DGS&D order. 15. CCAMP is a public funded research institute and is entitled to concessionalratc of GST @ 5%for certain items supplied for research purpose vide notification no. 47/2017 and 45/2017 dated 14th Nov, 2017. The offer should be submitted after fully considering the above notification. 16. Liquidity Damages:If the equipment/ items as per specifications in our P.O. is not supplied (shipped) within the specified delivery schedule, then liquidated damages (not in terms of penalty) will be imposed automatically and shall be deducted from the bill at the rate of 0.5% per week subject to a maximum of 10% of the order value. 17. Income Tax at the applicable rates as per the Indian Income Tax Act 1961 will be deducted at source for the services availed / ordered. In case of service provider, the rate of tax deduction shall be at 2% as per Section 194C, and in case of fee for professional / technical services |