Summary - Supply of Medicine and Medical / Surgical equipments : Cardiac Troponin I qualitative strips\n1. The Troponin assay test strip should be able\nto detect cardiac Troponin I(cTnI) in serum\n/plasma/whole blood cTnI.\n2. The method of analyzing cTn should be\nbased on double antibody lateral flow\nImmunoassay technique with specific\nantibodies to cTnI to provide maximum\nspecificity.\n3. The reaction time should be less than 20\nminutes for each test.\n4. Should be very sensitive with a cutoff point\nof cTnI not more than 1 ng/mL and preferably\n0.5 ng/mL.\n5. Stirp should have a built in quality control\nfeature control line" which indicates defective\nstripm inadequate volume or inadequate flow\nof the sample.\n6. Minimum serum volume required should be\nnot more than 200 micro litre.\n7. Traceability certificate should be available\n8. Supply of positive and Negative controls are\npreferable.\n9. Additional instruments should not be\nrequired to perform the test except using a\npipette and the strip. If any additional\ninstruments required, it should be supplied by\nthe strip provider “Free of charge” for all users.\n10. Should have Cosmetic Devices Drug\nAuthority (CDDA) / National Medicinal\nRegulatory Authority (NMRA) certificate.\nPacking : 25 strips etc .
Deadline - Apr 03, 2025
GT reference number - 103832741
Product classification - Pharmaceutical products
Address - Sri Lanka
Contact details - 565656565
Tender notice no. - 76454545
GT Ref Id - 103832741
Document Type - Tender Notices
Description - Description: Supply of Medicine and Medical / Surgical equipments : Cardiac Troponin I qualitative strips\n1. The Troponin assay test strip should be able\nto detect cardiac Troponin I(cTnI) in serum\n/plasma/whole blood cTnI.\n2. The method of analy zing cTn should be\nbased on double antibody lateral flow\nImmunoassay technique with specific\nantibodies to cTnI to provide maximum\nspecificity.\n3. The reaction time should be less than 20\nminutes for each test.\n4. Should be very sensitive with a cutoff point\nof cTnI not more than 1 ng/mL and preferably\n0.5 ng/mL.\n5. Stirp should have a built in quality control\nfeature control line" which indicates defective\nstripm inadequate volume or
Gt Ref Id - 103832741
Deadline - Apr 03, 2025
Similar Tenders :
Why Us
3,00,000 +
Users
190 +
Countries Covered
5,00,000 +
Agencies Tracked
50,000 +
Notices Daily
90 Million +
Database